跳到主要內容

【A01】標準麥克風互換校正系統

服務之儀器  電容式麥克風(Condenser Microphone) 
校正範圍  (1) 1英吋(符合IEC 61094-1 LS1)
  (1a) 1/3八音度,頻率:2 Hz to 12.6 kHz
  (1b) 1/1八音度,頻率:31.5 Hz to 8 kHz
(2) 1/2英吋(符合IEC 61094-1 LS2)
  (2a) 1/3八音度,頻率:10 Hz to 25.2 kHz
  (2b) 1/1八音度,頻率:16 Hz to 16 kHz 
不確定度  (1)  0.08 dB (2 Hz to 2.5 Hz),0.06 dB (2.5 Hz(不含) to 8 Hz),0.05 dB (8 Hz(不含) to 2 kHz),0.06 dB (2 kHz(不含) to 4 kHz),0.08 dB (4 kHz(不含) to 6.3 kHz),0.12 dB (6.3 kHz(不含) to 10 kHz),0.16 dB (10 kHz(不含) to 12.6 kHz)
(2) 0.06 dB (10 Hz to 16 Hz),0.05 dB (16 Hz(不含) to 3.2 kHz),0.06 dB (3.2 kHz(不含) to 8 kHz),0.08 dB (8 kHz(不含) to 10 kHz),0.12 dB (10 kHz(不含) to 16 kHz),0.14 dB (16 kHz(不含) to 20 kHz),0.22 dB (20 kHz(不含) to 25.2 kHz)
校正點數說明  (1a) 1/3八音度,頻率:2 Hz to 12.6 kHz,共39點
(1b) 1/1八度,頻率:31.5 Hz to 8 kHz,共9點
(2a) 1/3八音度,頻率:10 Hz to 25.2 kHz,共35點
(2b) 1/1八音度,頻率:16 Hz to 16 kHz,共11點
校正費用  (1a) (2a) 41,100元
(1b) (2b) 22,800元 
送校件須知  1.送校前必須保持清潔
2.原廠校正報告(Calibration Chart)宜伴隨送校 

(圖說) 本實驗室提供校正/驗證系統之服務規格說明及送校件須知等